Configure simulation control settings for UMF. OutdoorPlus

Input

Name Nickname Description
WriteInt Write interval in time steps. Optional; uses solver default if omitted.
Format Write format: 0=ascii, 1=binary, 2=compressed.
CPU Number of CPUs/subdomains to use. Optional; default is 1.
SolidStep Initial solid time step factor for UMF controlDict. Optional.
MinDT Minimum time step between iterations. Optional.
MaxDT Maximum time step between iterations. Optional.
MinFI Minimum fluid iterations per time step. Optional.
MaxFI Maximum fluid iterations per time step. Optional.
PcForm 'pc-based' or 'mixed' (default is pc-based).
DampThk Blending coefficients: damping thickness. Optional.
AlphaU Blending coefficients: alphaCoeffU. Optional.
AlphaT Blending coefficients: alphaCoeffT. Optional.

Output

Name Nickname Description
Settings Simulation control settings.